Automatic Melting Point Apparatus

Automatic Melting Point Apparatus

Automatic Melting Point Apparatus

Automatic Programmable Melting Point Apparatus
Model: µThermoCal50 | Make: ANALAB | HSN Code: 90278090

Supplied with Melting Capillary One End Sealed (Pack of 100 Nos.), Boiling Tube, Sample Tapping Rod, Five Melting Standards (ANALAB Certified), Forceps, Power Cord, Operational & Instruction Manual, Calibration Test Certificate and Warranty Card.

Technical Specification:
Temperature Controller : Microcontroller Based
Detection Principal of Melting Point : Automatic by Silicon Photodiode
Heating Media : By Aluminum Block
Temperature Range : +5°C above ambient to 350°C
Readability : 0.1°C
Accuracy of Temperature : A) +5°C above ambient to 200°C………… ± 0.2°C
B) 200°C to 350°C …………….. ±0.5°C
Overheating Protection : In-built - Set by user in method parameter
Heating Before Set Point (EMP) : Automatic heating depending upon temperature difference
Heating Rate : Variable 0.2, 0.5, 1.0, 2.0, 3.0 & 5.0 ºC/min - Selectable after Set Point (EMP)
Display : 20 x 4 Line Alphanumeric Backlit LCD
Detection of Melting : A) Melting Point B) Melting Range
Detection of Boiling Point : Manually by viewing in TFT Display – One Boiling Tube
Magnification : 5X
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Viewing of Melting Capillary : Camera with TFT Display for viewing Melting Capillary and Boiling Tube in CAPillary VIEW
Method : 40 method for Melting & 10 for Boiling sample with View, Print & Delete facility
Calibration : Seven Calibration Standards (As per Pharmacopeia AND / OR Customer's known standards)
Melting Capillary Ports : Three - one sample at a time
Glass Melting Capillary : OD: 1.4 to 1.6mm | ID: 1.0mm| Length: 100mm | One End Sealed
Sample Filling Height : 3mm
Password Protection : Date & Time, Calibration Mode, Delete Stored Analysis Data and Restore Factory Set Calibration Data
Maximum Heating Time : Around 6 minutes from 50°C to 350°C
Maximum Cooling Time : Around 6 minutes from 350°C to 50°C
Temperature Sensor: Duplex PT-100, One for internal used and One for calibration purpose by external source
Calibration Data Storage : Non Volatile Memory which can store, print & view calibration date & time, company name, standard name with temperature, actual reading of standard temperature, calibration done by, instrument serial number, instrument ID, model number etc.
Report Formation : As per GLP Compliance
Analysis Data Storage : More than 500 analysis data can be stored with corresponding calibration data with batch number/ID, users name, sample name, instrument serial number, instrument ID, model number, calibration point, calibration date & time, analysis date & time, upper & lower calibration standard based on sample temperature, heating rate, melting range (MP1 & MP2), signature etc. Secondly, analysis data can print directly from analysis mode without saving analysis data in instrument.
Printer Interface : Centronics Parallel Port / Serial Port
Printer : 40 / 80 Column Dot Matrix Printer (Printer have to procure optionally)
Power Supply : 230 VAC ±10%, 50 Hz

X
Provide Us More Details
Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Automatic Melting Point Apparatus ?

    country-ico

    We will contact you soon !

    Shirish Parmar

    (Director)

    Analab Scientific Instruments Private Limited

    Sayaji Park Society, Vadodara, Gujarat, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us