Conductivity-TDS-Temperature Analyzer

Conductivity / Temperature Analyzer

Conductivity / Temperature Analyzer

Auto Ranging Conductivity/ºC Analyzer
Model: µConCal5| Make: ANALAB | HSN Code : 90278090

Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Instruction & Operational Manual, Manufacturer Test Certificate and Warranty Card.

Technical Specification:
Conductivity Range : Up to 20.00, 200.0, 2000 µS/cm; 2 to 20.000, 200.00 mS/cm 
(Range value change depending upon cell selection)
Conductivity Resolution : 0.001, 0.01, 0.1 µS/cm & 0.001, 0.01 mS/cm
Range Selection : Auto / Manual Ranging
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Display : 16 x 2 Line Alphanumeric Backlit LCD.
Reading of Conductivity : At actual temperature and at 25°C by scrolling the display
Number of Range : Five
Calibration Standard : Five Conductivity Standard - One Per Range
Calibration Factor : Five – One Per Range
Error Messages : “Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range” & ”Temperature Probe Error”.
Temperature Range : 0 to 130°C
Temperature Calibration : Onsite by users with in-built software
Temperature Resolution : 0.1°C
Temperature Compensation : Auto / Manual
Temperature Coefficient : 0-10.000 % per °C (Adjustable) – One Per Range
Suitable Cell Constant : 0.1 & 1.0 K
Adjustable Cell Constant : 0.09 to 0.11 K & 0.90 to 1.1 K
Magnetic Stirrer Interface : Inbuilt with instrument (Magnetic stirrer have to
procure optionally and recommended for lower range conductivity standard for accurate result.)
Power Supply : DC Adaptor

Conductivity/TDS/Temperature Analyzer

Conductivity/TDS/Temperature Analyzer

Auto Ranging Conductivity/TDS/ºC Analyzer
Model: µConCal10 | Make: ANALAB | HSN Code : 90278090

Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual, Manufacturer Test Certificate and Warranty Card.

Technical Specification:
Conductivity Range : 0 to 20.00, 200.0, 2000 µS/cm;  2 to 20.00, 200.0 mS/cm
(Range value change depending upon cell selection)
Conductivity Resolution : 0.001, 0.01, 0.1 µS/cm & 0.001, 0.01 mS/cm
TDS Range : 0 to 10, 100, 1000, 10000, 100000 ppm (Depending upon Cell Constant & TDS factor)
TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01ppt* (1 ppt=1000 ppm)
Range Selection : Auto / Manual
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS.
Display : 16 x 2 Line Alphanumeric Backlit LCD.
Reading of Conductivity & TDS : At actual temperature and at 25°C & TDS value by scrolling the display
Number of Range : Five
Calibration Standard : Five Conductivity Standard - One Per Range
Calibration Factor : Five – One Per Range
Temperature Range : 0 to 130°C
Temperature Resolution : 0.1°C
Temperature Compensation : Auto / Manual
Temperature Coefficient : 0-10.000 % per °C (Adjustable) – One Per Range
Temperature Calibration : Onsite by users with in-built software
Suitable Cell Constant : 0.1, 0.5 & 1.0 K
Adjustable Cell Constant : 0.09 to 0.11 K, 0.452 to 0.55 K & 0.90 to 1.1 K
Conductivity to TDS Conversion Factor : 0.40000 to 1.00000 (Adjustable)
TDS Calibration & Analysis : In Separate Mode
Error Messages : “Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range” & ” Temperature Probe Error”.
Calibration Data Storage : Non Volatile Memory which can store, print & view with calibration date & time, cell constant, calibration range, standard conductivity solution, measured conductivity at 25°C & actual temperature, calibration factor, model number etc.
Analysis Data Storage : More than 500 analysis data can be stored with corresponding calibration date & time, company name, conductivity at 25°C and conductivity at actual temperature, conductivity to TDS conversion factor, TDS, model number etc. Secondly, analysis data can print directly from analysis mode without saving analysis data in instrument.
Printer Interface : Centronics Parallel Port
Printer : 40 Column Dot Matrix Printer (Printer have to procure optionally)
Magnetic Stirrer Interface : Inbuilt with instrument (Magnetic stirrer have to procure optionally and recommended for lower range conductivity for accurate result)
Power Supply : DC Adaptor

* ppt = parts per thousand


Additional Information:
X
Provide Us More Details
Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Conductivity-TDS-Temperature Analyzer ?

    country-ico

    We will contact you soon !

    Shirish Parmar

    (Director)

    Analab Scientific Instruments Private Limited

    Sayaji Park Society, Vadodara, Gujarat, India

    More Categories

    View All Categories »
    Send SMS
    Get Callback