Ph Mv C Orp Analyzer

pH/mV/Temperature/ORP Analyzer (Three Point Calibration)

pH/mV/Temperature/ORP Analyzer (Three Point Calibration)

pH/mV/ºC/ORP Analyzer (Three Point Calibration)
Model: µpHCal10 | Make: ANALAB | HSN Code : 90278090

Supplied with Combination Glass pH Electrode (0-70ºC), Standard Buffer Tablets (7.00 pH, 4.01 pH & 9.18 pH), Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual, Manufacturer Test Certificate and Warranty Card.

Technical Specification:
pH
 Range : -2.000 to 20.000 pH
 Resolution : 0.001 pH
Relative Accuracy : ± 0.002 pH
mV/ORP
 Range – mV/RmV : ± 2000.0
 ORP : EH auto calibration to standard hydrogen electrode
 Resolution : 0.1
 Relative Accuracy : ± 0.2 mV OR 0.05%, whichever is greater
Temperature
 Range : -5.0 to 130.0ºC
 Resolution : 0.1°C
Relative Accuracy : ± 0.1ºC
Slope : 80-120 %
Display : 16 x 2 Line Alphanumeric Backlit LCD
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Auto Buffer Recognition : 4.01, 6.86 / 7.00, 9.18 / 10.01 @ 25°C
Error Messages : “Bad Buffer / Electrode”, “Temperature Probe”, “Low Memory” & “pH Over Range”.
Temperature Compensation : Auto / Manual
Temperature Calibration : Onsite by users with in-built software
Buffer Standard : US / NIST & EURO
Measurement : Simultaneous of pH, mV & Temperature
Short Link : Provided to diagnose the problem either with Instrument OR Electrode.
Calibration Data Storage : Non Volatile Memory which can store, print & view with pH buffer, pH reading, temperature, slope, mV, offset and calibration date & time, model number etc.
Analysis Data Storage : More than 500 analysis data can be stored with corresponding calibration data, model number, analysis date & time, calibration date & time, company name, pH, mV & temperature. Secondly, analysis data can print directly from analysis mode without saving analysis data in Instrument.
Printer Interface : Centronics Parallel Port
Printer : 40 Column Dot Matrix Printer (Printer have to procure optionally)
Magnetic Stirrer Interface : Inbuilt with instrument (Magnetic stirrer have to
procure optionally)
Power Supply : DC Adaptor

X
Provide Us More Details
Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Ph Mv C Orp Analyzer ?

    country-ico

    We will contact you soon !

    Shirish Parmar

    (Director)

    Analab Scientific Instruments Private Limited

    Sayaji Park Society, Vadodara, Gujarat, India

    More Categories

    View All Categories »
    Send SMS
    Get Callback